Two Isolating valves and one equalizing valve are designed in a single body, making the
manifold ideal for on-line instrument calibration. Integral valve construction
eliminates the use of numerous valves, nipples and fittings.
H-Type 3 way
H-Type manifolds is designed for close mounting differential pressure instruments to
orifice flanges or orifice changer fittings.The flanged valve outlet is bolted directly
to the pressure transmitter body. By bolting standard football flanges to the manifold
inlet, the complete assembly can be close coupled to orifice flange taps using eccentric
solid bar stock nipples. These manifold valves provide a simple, rugged and dependable
installation.
T-Type 5 way
This manifold valve mounts directly to the differential pressure transmitter. The two
Isolating valves allow easy removal of the instrument for servicing and the three valves
on top of the manifold provide an easy method for accurate field calibration using the
manifold vent connection rather than the instrument drain connections.
T-Type 3 way
This manifold valve mounts directly to the differential pressure transmitter. The two
hovalves allow easy removal of the instrument for servicing.